![Siemens SCALANCE S615 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/siemens/scalance-s615/scalance-s615_configuration-manual_377351033.webp)
Description
1.6 General CLI commands
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
33
1.6.5.3
Completion of command entries
Description
The command interpreter of the Command Line Interface supports you when you enter
commands.
As soon as the first characters of the command have been entered in the input line, the
system can complete the entry as long as the character string is unambiguous.
This can be repeated after entering further characters.
Procedure
Enter the first characters of the command.
Press the tab key.
Result
The command interpreter completes the input as long as the command is unambiguous.
If you enter a character string that cannot be completed to form a command, an error
message is displayed.
●
The command is not unique:
% Ambiguous Command
●
The command is unknown:
% Invalid Command
●
The command is incomplete:
% Incomplete command
If the entry is not yet complete, enter further characters.
With
?
, you obtain a list of the possible commands.
Repeat this if necessary until the command is complete and can execute.
Содержание SCALANCE S615
Страница 6: ...Preface SCALANCE S615 Command Line Interface 6 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 130: ...System time 4 2 NTP client SCALANCE S615 Command Line Interface 130 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 138: ...System time 4 3 SNTP client SCALANCE S615 Command Line Interface 138 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 170: ...Network structures 5 1 VLAN SCALANCE S615 Command Line Interface 170 Configuration Manual 06 2015 C79000 G8976 C406 02 ...
Страница 302: ...Layer 3 functions 8 1 NAT SCALANCE S615 Command Line Interface 302 Configuration Manual 06 2015 C79000 G8976 C406 02 ...