Contact
Assignment
+DI
Input
-DI
Ground
If there is an adequate switching voltage at the digital input, the digital input is active and
the "DI" LED is lit.
The voltage applied to the "DI" contact is converted to a digital status by the device as follows:
Voltage
Status
-30 to +3 V DC
0
+13 to +30 V DC
1
Digital output
The 2-pin terminal block has the following assignment:
'2
'2
9
9
Connecting up
5.4 Digital input/output
SCALANCE M826
48
Operating Instructions, 10/2022, C79000-G8976-C362-07