RUGGEDCOM WIN5237-IS
Installation Guide
Chapter 2
Installing the Subscriber Unit
Assembling the PoE Connector
17
3
1
2
Figure 10: Bending the Drain Wire
1.
Foil
2.
Drain Wire
3.
Twisted-Pair Wires
5. Partially untwist each wire pair, making sure to retain a half twist at the end.
Figure 11: Untwisting the Wire Pairs
6. Arrange the wires according to the following pin-out description:
1
2
Figure 12: CAT-5e PoE Cable Pin-Out
1.
Pin 1
2.
Pin 8
Pin
Number
Color
Description
1
White/Orange
ETH Data
TP0+
2
Orange
ETH Data
TP0-
3
White/Green
ETH Data
TP1+
4
Blue
48 V
TP2+
5
White/Blue
48 V
TP2-
6
Green
ETH Data
TP1-
7
White/Brown
RTN (-)
TP3+
8
Brown
RTN (-)
TP3-
7. Slide the wires into the loading bar and then pull the loading bar down until its face is 16 mm (0.63 in) from
the wire jacket. If necessary, use pliers to hold the wires while pulling the loading bar.