Certification
IEEE
29
IMPORTANT!
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate this device.
Section 5.1.5
IEEE
This subscriber unit complies with the Mobile WiMAX Forum Wave 2 requirements defined by the following
Institute of Electrical and Electronics Engineers (IEEE) standards:
•
IEEE 802.16-2005
IEEE Standard for Local and Metropolitan Area Networks – Part 16: Air Interface for Fixed and Mobile Broadband
Wireless Access Systems – Amendment for Physical and Medium Access Control Layers for Combined Fixed and
Mobile Operation in Licensed Bands
Section 5.1.6
RoHS
This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of
Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic
equipment:
•
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic Information Products
A copy of the Material Declaration is available online at
https://support.industry.siemens.com/cs/ww/en/
Section 5.2
Environmental Type Tests
The RUGGEDCOM WIN5237-IS has passed the following environmental tests.
Test
Description
Test Levels
IEC 60068-2-1
Low Temperature
-25 °C for 72 hours
-40 °C (-40 °F) for 16 hours
-40 °C (-40 °F) for 72 hours
IEC 60068-2-2
High Temperature
55 °C (131 °F) for 72 hours
60 °C (140 °F) for 16 hours
70 °C (158 °F) for 72 hours
IEC 60068-2-11
MIL-STD-810F 509.4
Salt Fog
5% NaCI 35° 48h
IEC 60068-2-14
Temperature Change
-10 to 45 °C (14 to 113 °F) @ 0.5 °C/min (0.9 °F/min) for 2 cycles
-40 to -30 °C (-40 to -22 °F) @ 1 °C/min (1.8 °F/min) for 5 cycles
IEC 60068-2-18
Water (Rain, Intensity)
0.01 m³/min (0.35 ft³/min @ 90 kPa (13 PSI) for 30 minutes