RUGGEDCOM WIN5114-V
Installation Guide
Chapter 1
Introduction
Required Tools and Materials
3
12VDC Port
A 4-pin, female, D-Coded M12 port for power. For more information about connecting data
and power, refer to
Section 2.7, “Connecting Power and Data”
ANT 1 and ANT 2 Ports
Ports for connecting primary and secondary external antennas. For information about
connecting the antennas, refer to
Section 2.5, “Installing the Antennas”
.
RSSI LEDs
Indicates the received signal strength.
LED
RSSI Level
< -90
-85 to -90
-80 to -85
-75 to -80
-70 to -75
-65 to -70
-20 to -60
> -20
W.LINK LED
Indicates when the subscriber unit is connected with a base station.
State
Description
Green (Solid)
Subscriber unit is connected to the base
station and receiving services.
Green (Blinking)
Link between the subscriber unit and the
base station is down.
PWR LED
Indicates when power is supplied to the subscriber unit.
State
Description
Green
Power is on.
Off
Power is off.
ETH Port
A 4-pin, female, D-Coded M12 port for data.
Chassis Ground Connection
Protects the subscriber unit from power surges and accumulated static electricity. For
information about grounding the subscriber unit, refer to
Section 1.3
Required Tools and Materials
The following tools and materials are required to install the RUGGEDCOM WIN5114-V:
Tools
• Wrench or socket set
• Phillips screwdriver
• Drill with an 8 mm (5/16 in) drill bit
• Wall anchors (if necessary)
Greases
• Marine grease (for marine applications only)
Tapes
• POE cold shrink (maximum 49.2 mm or 1.9 in inner
diameter before shrinking) or self-amalgamating tape