RUGGEDCOM RST2228
Installation Guide
Chapter 5
Technical Specifications
Power Supply Specifications
31
Technical Specifications
This section provides important technical specifications related to the device.
CONTENTS
•
Section 5.1, “Power Supply Specifications”
•
Section 5.2, “Failsafe Alarm Relay Specifications”
•
Section 5.3, “Supported Networking Standards”
•
Section 5.4, “Operating Environment”
•
Section 5.5, “Mechanical Specifications”
•
Section 5.6, “Dimension Drawings”
Section 5.1
Power Supply Specifications
NOTE
When determining cable lengths, make sure the minimum input voltage for the power supply is
provided at the power source.
NOTE
Use the internal fuse rating to determine the size of the external circuit breaker/fuse.
Input Range
Power
Supply Type
Terminal
Block Type
Min
Max
Internal
Fuse Rating
Maximum Power
Consumption
a
Wire Gage
12 VDC (Single)
10.5 VDC
15 VDC
12 A
77 W
#14 AWG
24 VDC (Single)
13 VDC
36 VDC
10 A
72 W
#14 AWG
48 VDC (Single)
Screw
36 VDC
72 VDC
5 A
72 W
#16 AWG
88 VDC
300 VDC
77 W/ 76W
High Voltage
AC/DC
Screw/Pluggable
85 VAC
264 VAC
3.15 A
75 W/ 75W
#16 AWG
a
Based on nominal input voltages and 60W output load.
Содержание RUGGEDCOM RST2228
Страница 30: ...Chapter 3 Device Management RUGGEDCOM RST2228 Installation Guide 24 Inserting Removing the CLP ...
Страница 36: ...Chapter 4 Communication Ports RUGGEDCOM RST2228 Installation Guide 30 Installing Removing Modules ...
Страница 42: ...Chapter 5 Technical Specifications RUGGEDCOM RST2228 Installation Guide 36 Dimension Drawings ...
Страница 50: ...Chapter 6 Certification RUGGEDCOM RST2228 Installation Guide 44 EMC and Environmental Type Tests ...