The RUGGEDCOM RSL910 has passed the following Electromagnetic Compatibility (EMC) and environmental tests.
EMC Type Tests
Test
Description
Test Levels
Severity Levels
Enclosure Contact
± 6 kV
3
IEC 61000-4-2
ESD
Enclosure Air
± 8 kV
3
IEC 61000-4-3
Radiated RFI
Enclosure Ports
10 and 20 V/m
3
Signal Ports
± 2 kV
4
DC Power Ports
± 2 kV
3
AC Power Ports
± 2 kV
3
IEC 61000-4-4
Burst (Fast Transient)
Earth
Ground Ports
± 1 kV
2
Signal Ports
± 2 kV
2
DC Power Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
1
IEC 61000-4-5
Surge
AC Power Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
2
Signal Ports
10 V
3
DC Power Ports
10 V
3
AC Power Ports
10 V
3
IEC 61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V
3
IEC 61000-4-8
Magnetic Field
Enclosure Ports
30 A/m
IEC 61000-4-11
Voltage Dips and Interrupts
AC Power Ports
30% for 25 Periods
60% for 10 Periods
100% for 1 Period
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ae
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Be
85 °C (185 °F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (Non-Condensing),
55 °C (131 °F), 6 Cycles
IEC 60255-21-1
Vibration
2 g @ 10 to 150 Hz
Class 2
IEC 60255-21-2
Shock
30 g @ 11 ms
Class 2
Содержание RUGGEDCOM RSL910
Страница 4: ...RUGGEDCOM RSL910 Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RSL910 Installation Guide x Customer Support ...
Страница 16: ...Chapter 1 Introduction RUGGEDCOM RSL910 Installation Guide 6 Supported Fiber Optic Cables ...
Страница 30: ...Chapter 3 Device Management RUGGEDCOM RSL910 Installation Guide 20 Configuring the Device ...
Страница 38: ...Chapter 4 Communication Ports RUGGEDCOM RSL910 Installation Guide 28 SFP Transceivers ...