Chapter 4
Communication Ports
RUGGEDCOM RSL910
Installation Guide
26
SFP Transceivers
Distance
Downstream/Upstream (Mbps)
SNR (dB)
2438 m (8000 ft)
2.4/2.4
10
3048 m (10000 ft)
1.2/1.2
10
3353 m (11000 ft)
0.5/0.5
10
Data Rates vs. SNR Margin
The following typical data rates are achievable with the corresponding Signal-to-Noise ratio, at a fixed cable length
of 0.9m (3ft).
Distance
Downstream/Upstream (Mbps)
SNR (dB)
0.9 m (3 ft)
140/140
10
0.9 m (3 ft)
120/120
15.3
0.9 m (3 ft)
100/100
19.8
0.9 m (3 ft)
85/85
23.6
0.9 m (3 ft)
55/55
29.8
0.9 m (3 ft)
35/35
34.6
0.9 m (3 ft)
25/25
37.3
0.9 m (3 ft)
11/11
38.3
0.9 m (3 ft)
4.7/4.7
41.7
0.9 m (3 ft)
2.4/2.4
42.8
0.9 m (3 ft)
1.2/1.2
43.4
0.9 m (3 ft)
0.5/0.5
43.8
0.9 m (3 ft)
0.2/0.2
44
Section 4.3
SFP Transceivers
The RUGGEDCOM RSL910 supports up to two Small Form-Factor Pluggable (SFP) transceiver sockets, which are
compatible with a wide array of SFP transceivers available from Siemens.
LEDs
Each socket features an LED that indicates its link state.
State
Description
Yellow (Solid)
Link established
Yellow (Blinking)
Activity
Off
No link detected
Содержание RUGGEDCOM RSL910
Страница 4: ...RUGGEDCOM RSL910 Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RSL910 Installation Guide x Customer Support ...
Страница 16: ...Chapter 1 Introduction RUGGEDCOM RSL910 Installation Guide 6 Supported Fiber Optic Cables ...
Страница 30: ...Chapter 3 Device Management RUGGEDCOM RSL910 Installation Guide 20 Configuring the Device ...
Страница 38: ...Chapter 4 Communication Ports RUGGEDCOM RSL910 Installation Guide 28 SFP Transceivers ...