Installing the Device
Connecting the Failsafe Alarm Relay
11
Section 2.4
Connecting the Failsafe Alarm Relay
The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed
when the unit is powered and there are no active alarms. If the device is not powered or if an active alarm is
configured, the relay opens the NO contact and closes the NC (Normally Closed) contact.
NOTE
Control of the failsafe relay output is configurable through ROS. One common application for this relay
is to signal an alarm if a power failure occurs. For more information, refer to the ROS User Guide for
the RUGGEDCOM RSL910.
To connect the failsafe alarm relay, do the following:
1. Insert the failsafe alarm relay terminal block into the device and tighten the screws.
2. Connect a failsafe device to the terminal block.
1
2
3
Figure 5: Failsafe Alarm Relay Wiring
1.
Normally Closed
2.
Common
3.
Normally Open
Section 2.5
Connecting Power
The RUGGEDCOM RSL910 supports power input from a single high AC/DC or low DC power supply.
IMPORTANT!
• For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
• For 125/250 VDC rated equipment, an appropriately rated DC circuit breaker must be installed.
• Use minimum #16 gage copper wiring when connecting terminal blocks.
• Equipment must be installed according to applicable local wiring codes and standards.
• All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases where users
require the inputs to be isolated from ground, remove the ground braid between Surge and Chassis
Ground. Note that all line-to-ground transient protection circuitry will be disabled.
Содержание RUGGEDCOM RSL910
Страница 4: ...RUGGEDCOM RSL910 Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RSL910 Installation Guide x Customer Support ...
Страница 16: ...Chapter 1 Introduction RUGGEDCOM RSL910 Installation Guide 6 Supported Fiber Optic Cables ...
Страница 30: ...Chapter 3 Device Management RUGGEDCOM RSL910 Installation Guide 20 Configuring the Device ...
Страница 38: ...Chapter 4 Communication Ports RUGGEDCOM RSL910 Installation Guide 28 SFP Transceivers ...