RUGGEDCOM RSG2488
Installation Guide
Chapter 4
Technical Specifications
Power Supply Specifications
33
Technical Specifications
This section provides important technical specifications related to the device.
CONTENTS
•
Section 4.1, “Power Supply Specifications”
•
Section 4.2, “Failsafe Alarm Relay Specifications”
•
Section 4.3, “Supported Networking Standards”
•
Section 4.4, “Operating Environment”
•
Section 4.5, “Mechanical Specifications”
Section 4.1
Power Supply Specifications
NOTE
Use the internal fuse rating to determine the size of the external circuit breaker/fuse.
Input Range
Power
Supply Type
Terminal
Block Type
Min
Max
Internal
Fuse Rating
Maximum Power
Consumption
Maximum
Cable Length
a
24 VDC (Single)
13 VDC
36 VDC
10 A
62 W
9.4 m (30.8 ft)
48 VDC (Single)
Screw
38 VDC
72 VDC
5 A
59 W
44.9 m (167 ft)
98 VDC
300 VDC
High Voltage
AC/DC
Screw/Pluggable
88 VAC
264 VAC
3.15 A
66 W
—
a
Based on #16 AWG wiring.
Section 4.2
Failsafe Alarm Relay Specifications
IMPORTANT!
The alarm switching voltage must be greater than the Safety Extra Low-Voltage (SELV) to meet safety
requirements.
Parameter
Value (Resistive Load)
Maximum Switching Voltage
250 VAC
Содержание RUGGEDCOM RSG2488
Страница 4: ...RUGGEDCOM RSG2488 Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RSG2488 Installation Guide x Customer Support ...
Страница 14: ...Chapter 1 Introduction RUGGEDCOM RSG2488 Installation Guide 4 Description ...
Страница 30: ...Chapter 2 Installing the Device RUGGEDCOM RSG2488 Installation Guide 20 Configuring the Device ...
Страница 46: ...Chapter 4 Technical Specifications RUGGEDCOM RSG2488 Installation Guide 36 Mechanical Specifications ...