Certification
6.1.6 RoHS
6.1.6
RoHS
This device is declared by Siemens AG to meet the requirements of the following Ro-
HS (Restriction of Hazardous Substances) directives for the restricted use of certain
hazardous substances in electrical and electronic equipment:
•
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic Informa-
tion Products
A copy of the Material Declaration is available online at
try.siemens.com/cs/ww/en/view/109738831
6.1.7
Other Approvals
This device meets the requirements of the following additional standards:
•
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RS910L has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test
Description
Test Levels
Severi-
ty Levels
Enclosure
Contact
± 8 kV
4
IEC
61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC
61000-4-3
Radiated RFI
Enclo-
sure Ports
20 V/m
Signal Ports
± 4 kV @ 2.5 kHz
x
DC Pow-
er Ports
± 4 kV
4
AC Pow-
er Ports
± 4 kV
4
IEC
61000-4-4
Burst (Fast Transient)
Earth
Ground Ports
± 4 kV
4
Signal Ports
± 4 kV Line-to-Ground
± 2 kV
4
IEC
61000-4-5
Surge
DC Pow-
er Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
3
RUGGEDCOM RS910L
Installation Manual, 02/2020, C79000-G8976-1030-06