Installing the Device
2.5.1 Connecting High AC/DC Power
2. Connect the positive wire from the power source to the positive/live (+/L) termi-
nal on the terminal block.
4
1
2
3
1
Positive/Live (+/L) Terminal
2
Negative/Neutral (-/N) Terminal
3
Surge Ground Terminal
4
Braided Ground Cable
Figure 2.5
Terminal Block Wiring
RUGGEDCOM RS910L
Installation Manual, 02/2020, C79000-G8976-1030-06
15