Installing Device
2.3 Connecting the Failsafe Alarm Relay
Figure 2.10
Dual AC/DC Power Supply
2.3
Connecting the Failsafe Alarm Relay
The failsafe relay can be configured to latch based on alarm conditions. The NO
(Normally Open) contact is closed when the unit is powered and there are no active
alarms. If the device is not powered or if an active alarm is configured, the relay
opens the NO contact and closes the NC (Normally Closed) contact.
Note
Control of the failsafe relay output is configurable through RUGGEDCOM RS1600F .
One common application for this relay is to signal an alarm if a power failure
occurs. For more information, refer to the
RUGGEDCOM RS1600F User Guide
for the
RUGGEDCOM RS1600F.
The following shows the proper relay connections.
1
2
3
1
Normally Closed Terminal
2
Common Terminal
3
Normally Open Terminal
Figure 2.11
Failsafe Alarm Relay Wiring
RUGGEDCOM RS1600F
Installation Manual, 01/2021, C79000-G8976-1014-03