Installing peripherals
5.1.3
Attaching the system unit to a LAN
Figure 17: Attaching the system unit to a LAN
In its base configuration the system has one Ethernet controller. You can also install
additional LAN controllers in the free slots on the system unit backplane.
The Ethernet controller built into the motherboard is a precondition for remote instal-
lation of the Reliant UNIX operating system (see the manual “Reliant UNIX Instal-
lation and Operation - RM200, RM300, RM400” or the corresponding manual for
SINIX V5.42).
The two LAN controller ports for Ethernet AUI (1) and twisted-pair (10BaseT) (2)
cannot both be used at once.
Attachment via AUI (Attachment Unit Interface)
Ê
Plug the connector on the LAN transceiver cable into socket (1).
Ê
Secure the connector by snapping the retaining clip into position.
Attachment via twisted-pair (10BaseT)
Ê
Plug the connector on the twisted-pair cable into socket (2). The connector
must lock into place.
1
2