3.8.1 Displaying and correcting parameters
A parameter number can be selected from the parameter level directly with the numerical
keys or with "Raise"/"Lower". The parameter number is shown as a three-figure quantity.
In the event of four-figure parameter numbers, the first figure (1, 2 or 3) is not displayed.
A distinction is made with the letters (P, H, U etc.).
Ê
Ê
0
Ì
Ì
Ê
Ê
4
Ì
Ì
Ê
Ê
9
Ì
Ì
r001 9
Drive status
Ready
r000
r004
r049.001
4
OP OperDisp
1st line,on left
Example: Direct input of the parameter number with the numerical keypad
Ê
Ê
∆
Ì
Ì
Ê
Ê
∆
Ì
Ì
Ê
Ê
∆
Ì
Ì
r001 9
Drive status
Ready
r002
0 min-1
Actual speed
r004
0.0 A
Output Amps
r006
0 V
DC Bus Volts
Example: Correcting the parameter number by means of "Raise"
If the parameter is found not to exist when the number is entered, a message "No PNU"
appears. A non-existent parameter number can be skipped by selecting "Raise" or
"Lower".
How the parameters are shown on the display depends on the type of parameter. There
are, for example, parameters with and without an index, with and without an index text
and with and without a selection text.
P704.001
0 ms
SCom TlgOFF
Ser. interf.1
Example: Parameter with index and
index text
1st line:
Parameter number, parameter index
2nd line: Parameter value with unit
3rd line: Parameter name
4th line: Index text