OP1S Operator Control Panel
Siemens AG
477 459 4070 72 J AA-6R
SIMOVERT MASTERDRIVES
Operating Instructions
19
Selection of
parameter value
Selection of bit
Correction of
bit
Accept and return
Ê
Ê
P
Ì
Ì
Ê
Ê
∆
Ì
Ì
Ê
Ê
0
Ì
Ì
Ê
Ê
P
Ì
Ì
P053 0006Hex
Parameter Access
0000000000000110
ComBoard: No
P053 0006Hex
Parameter Access
0000000000000110
ComBoard: No
P053 0006Hex
Parameter Access
0000000000000110
BaseKeyp: Yes
P053 0006Hex
Parameter Access
0000000000000100
BaseKeyp: No
P053 0004Hex
Parameter Access
0000000000000110
BaseKeyp: No
Parameters may also be displayed without a parameter number, for example during
quick parameterizing or if "Fixed setting" is selected. In this case, parameterization is
carried out via various sub-menus.
Example of how to proceed for a parameter reset
2x
Ê
Ê
P
Ì
Ì
Ê
Ê
P
Ì
Ì
Ê
Ê
∇
Ì
Ì
0.0 A 0 V 00
# 0.00 min-1
* 0.00 min-1
Ready
MotionControl
*Menu selection
OP: Upread
OP: Download
Menu selection
*User Param.
Param Menu..
Fixed set...
Menu selection
*User Param.
Param Menu..
#Fixed set...
Selection of fixed setting
P
Ì
Ì
Ê
Ê
∇
Ì
Ì
Ê
Ê
P
Ì
Ì
Ê
Ê
∆
Ì
Ì
Fixed setting
*Select FactSet
FactSet
Fixed setting
* Select FactSet
#FactSet
Factory setting
FactSet
*No FactSet
Factory setting
#FactSet
* No FactSet
Selection of factory setting
P
Ì
Ì
Ê
Ê
...
Ì
Ì
Factory setting
#FactSet
*No FactSet
busy............
Menu selection
*User Param.
Param Menu..
FixedSet...
Start of factory setting
NOTE
It is not possible to start the parameter reset in the "RUN" state.