Mounting and installing MindConnect Elements
4.4 LED lights of MindConnect Elements
Getting Connected to MindSphere
Getting Started, 05/2018
27
Error
Problem
Possible cause
Possible remedy
MCN L2- ERROR LED
blinking RED
IoT2040 USER LED
blinking RED
Data loss
MindConnect Nano/IoT2040
o was too long offline, so it
could not send data to
MindSphere and the storage
is full.
•
Check outbound
connection
•
Check Ethernet cables
•
Check Proxy (IP address,
User Authentication can
be required)
MCN L2- ERROR LED
RED
IoT2040 USER LED
Firmware update error
•
Technical problems with
a new version of firmware
•
Incorrect firmware type
•
Certificate problems
Authentication problems
etc.
•
Make sure that you are
using the correct
firmware type
(MindConnect
Nano/IoT2040).
•
MindConnect
Nano/IoT2040 will
automatically restart and
then firmware update will
be carried out after a
while.
•
If MindConnect
Nano/IoT2040 does not
restart automatically,
then restart it manually:
by switching on and off
the “power button” on
MindConnect Nano.and
by switching off/on the
power supply for
MindConnect IoT2040
Содержание MindConnect IoT2040
Страница 15: ...Overview of MindConnect Elements Getting Connected to MindSphere Getting Started 05 2018 15 ...
Страница 16: ......
Страница 30: ......
Страница 40: ......
Страница 65: ...Configuring data in Asset Manager 7 4 Datamapping Getting Connected to MindSphere Getting Started 05 2018 65 ...
Страница 66: ......
Страница 74: ......
Страница 91: ...Appendix A 6 List of abbreviations Getting Connected to MindSphere Getting Started 05 2018 91 ...
Страница 92: ......