IONPURE
®
VNX50HH-2 CEDI Modules
Page 26
IP-MAN-VNX50HH2
1. Follow the instructions in Section 6.5 to prepare the VNX system for cleaning or
sanitization. Make sure that the cleaning tank drain valve is closed.
2. Fill the tank with the required amount of water.
3. Dissolve required amount of sodium chloride (NaCl) in the tank water.
4. Open the cleaning pump suction valve and bypass valve completely.
5. Divert the product and reject to drain.
6. Start the cleaning pump. When chemicals are well mixed, gradually open the
cleaning pump discharge valve while closing the cleaning pump bypass valve to
adjust the product and reject flow rates to the values given in Section 6.5.
7. Flush the salt solution to drain for about 3 minutes.
8. Turn off the cleaning pump.
9. Drain the tank.
STEP 2: Water Flush To Drain
Water flush rinses the salt solution from the module before cleaning solution is introduced.
Chemical necessary for Step 2
:
VNX50-HH
Water (RO permeate or CEDI product)
180 gal (675 liters)
1.
Fill the tank with the required amount of water.
2.
Start the cleaning pump and flush to drain for about three minutes.
3.
Turn off the cleaning pump.
4.
Drain the tank.
STEP 3: Cleaning Solution Recirculation
This 1% sodium percarbonate step removes organics and biofilm.
Chemicals necessary for Step 3
(1% 2Na
2
CO
3
3H
2
O
2
) sodium percarbonate:
VNX50-HH
Water (RO permeate or CEDI product)
99 gal (375 liters)
100% Sodium carbonate (Na
2
CO
3
)
8.25 lbs (3.75 kg)
30% Hydrogen peroxide (H
2
O
2
)
2.4 gal (8.4 liters)
1.
Close the cleaning pump discharge valve.
2.
Connect the product and reject lines to the cleaning tank.
3.
Fill the tank with the required amount of water.
4.
Dissolve the sodium carbonate (Na
2
CO
3
) in the water. Make sure the sodium
carbonate is fully dissolved before proceeding to the next step.
5.
Mix the 30% hydrogen peroxide (H
2
O
2
) into the solution in the tank.
6.
Open the cleaning pump suction valve and bypass valve completely.
Содержание IONPURE VNX50HH-2
Страница 40: ...IONPURE VNX50HH 2 CEDI Modules Page 40 IP MAN VNX50HH2 APPENDIX B VNX50HH LAYOUT ELEVATION DRAWING B 1 ...
Страница 41: ...IONPURE VNX50HH 2 CEDI Modules Page 41 IP MAN VNX50HH2 APPENDIX B VNX50 HH PID DRAWING B 2 ...
Страница 42: ...IONPURE VNX50HH 2 CEDI Modules Page 42 IP MAN VNX50HH2 APPENDIX B VNX50 HH ELECTRICAL CONNECTIONS DRAWING B 3 ...
Страница 46: ...IONPURE VNX50HH 2 CEDI Modules Page 46 IP MAN VNX50HH2 APPENDIX C VNX50 HH PP PLUG DRAWING C 4 ...