Connecting cables to the HiPath Wireless Outdoor AP
HiPath Wireless Outdoor AP cables
9034532, October 2009
HiPath Wireless Outdoor AP Installation Guide
29
4.1 HiPath Wireless Outdoor AP cables
Cable specification
The following table lists the requirements for a cable depending on the use case.
Warning notices cULus haz.loc
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D; Class I, Zone 2,
Group IIC or non-hazardous locations.
WARNING - Cat. Nos. EAP-Wx-yy-zx (US installation only):
•
PLTC cable type and manufacturer shall be specified: Listed (QPTZ), Type 5240U1 (Waterdog PLTC-ER)
manufactured by Belden.
•
The PLTC cable for the power supply must be installed in a manner to avoid tensile stress at the
termination fittings in accordance with Article 501.10 (B)(1)(4) of the NEC.
•
The PLTC cable for the power supply must be installed in accordance with Article 725.154 (D)(1) through
(D)(4) of the NEC.
WARNING -Cat. Nos. EAP-Wx-yy-zx (Canadian installation only):
•
TC cable type and manufacturer shall be specified: Listed (QPOR), Type JZ-604 TC manufactured by
Helukabel GmbH.
•
The TC cable for the power supply must be installed in areas of industrial establishments that are
inaccessible to the public and in a manner that meets the requirements in Rule 12- 2202(2) of the CEC:
Installed in conduit, other suitable raceway, or direct buried, when not in cable tray. Provided with
mechanical protection where subject to damage either during or after installation.
Installed only where qualified persons service the installation.
When operated in potential hazardous areas:
WARNING - Explosion Hazard – Do not disconnect while circuit is live unless area is known to be non-
hazardous
WARNING - Explosion Hazard – Substitution of components may impair suitability for Class I, Division 2
or Zone 2
Application
Specification
Power supply adapter 110-230 V AC
•
Round cable cross-section with 6 to 8 mm
diameter.
•
Three-core cable with 0.5-1.5 mm cross-
section of the individual cores.
•
Permitted tensile load at least 100 N.
Table 3
Cable specification