Version and setting inquiry
The SRIF 2002 responds to the command 990# (version inquiry) with its soft- and
hardware-dependent version number and its current settings for channel, transfer
rate, status of the RSSI extension. The “Special Channels” switch (SRIF 2000:
998/999) is also output to ensure compatibility with the SRIF2000. This switch has
no function for the SRIF2002.
The version number lies within the range of 200 and 299. The individual pieces of
information are separated from each other by “,” and are contained in the response
string in the above mentioned sequence (202,035,994,997,998#.)
Example response:
Data string
Version number 202 =
SRIF2002 / V02
202
Channel 4,
035
Transfer rate 57,600,
994
RSSI extension “ON”
997
Special channels
“OFF”:
998#