Functional Description
10/2003
Operating Instructions SRIF 2002
Page 18 of 33
Baud rate setting
Setting the transfer rate:
Transfer rate (baud)
Data string
9,600
991#
19,200
992#
38,400
993#
57,600
994#
115,200
995#
RSSI voltage / RSSI extension
The SRIF 2002 offers two settings for the output of RSSI voltage. With the "RSSI
extension" activated in the delivery state, the SRIF 2002 always raises the RSSI
voltage to a level of approx. 4V if received data are output at pin 4 (RxD).
If the “RSSI extension” is switched off, the RSSI level is not raised to 4 Volt during
the data output.
RSSI extension
Data string
ON
997#
OFF
996#