7
A fault, what to do?
If the fault could not be eliminated, please call customer service.
Fault
Cause
Solution
Who
Water flow-rate is too low. The
appliance does not switch on.
The filter in either the water tap
or the showerhead is clogged.
Remove the filter and either
clean it or descale it.
Customer
The filter in the corner regulating
valve is clogged.
Clean the filter.
Servicing expert
The water is not warm.
The fuse in the house electrical
installation has triggered/blown.
Check the fuse in the house
electrical installation.
Customer
The appliance’s automatic
circuit breaker has been
triggered.
Check the appliance’s auto-
matic circuit breaker. Check the
permissible supply temperature.
Servicing expert
The water is not sufficiently
warm.
The power limit has been
reached. Water flow-rate is too
high and/or the cold water
supply temperature is too low.
Reduce the flow-rate at the
water faucet supply.
Customer
Use the angle valve to regulate
the flow-rate.
Check the flow-rate limiter or
replace it with a smaller one.
Servicing expert
The second stage in the appli-
ance does not switch on (the
audible “clicking” is missing).
Remove the filter in the water
faucet and either clean it or
descale it.
Customer
Clean the filter in the corner
regulating valve.
Servicing expert
GB
Содержание DH 12400DH 12401DH 18400
Страница 9: ...4 4 3 I 5 1 1 2 ...
Страница 10: ...II 100 1 2 3 4 388 ca 96 70 44 100 ca 72 332 5 ...
Страница 11: ...III max 17 mm max 31 mm ca 2 mm ca 16 mm 3 4 2 1 ...
Страница 13: ...V min 40 mm 0 mm L1 L2 L3 PE min 40 mm 2 RESET 1 L1L2L3PE 6 5 3 4 ...
Страница 14: ...VI 3 4 1 2 5 6 7 8 L 3 L 2 L 1 3 2 1 PE PE 2 1 3 A B ...