7 Specifications
Issue 03/01
MICROMASTER 411 & COMBIMASTER 411 Operating Instructions
94
6SE6400-5CA00-0BP0
7.1 Technische
Daten
Table 7-1
MICROMASTER 411 / COMBIMASTER 411, Leistungsdaten
Eigenschaften Werte
Power supply Operating Voltage &
Power Ranges
380 to 480 V
±
10% 3AC
0.37 kW to 3.0 kW
Input Frequency
47 to 63 Hz
Cos phi
≥
0,95
Inverter Efficiency
94 % to 97 % at maximum power
Overload Capability
50 % overload capability for 60 s within 5 min referred to the nominal output
current
Inrush Current
Less than 4 A for CSB and less than 7.7 A for CSC.
Control Method
Linear V/f; Flux Current Control (FCC); Quadratic V/f; Multi-point V/f.
Pulse Frequency
2 kHz to 16 kHz (2 kHz steps) 4 kHz default
Fixed Frequencies
7, programmable
Skip Frequencies
4, programmable
Setpoint Resolution
0.01 Hz Digital, 0.01 Hz Serial, 10 bit Analog
Output Frequency Resolution
0.01 Hz Digital, 0.01 Hz Serial, 10 bit Analog
Digital Inputs
3, programmable (isolated), switchable active high / active low (PNP/NPN)
Analogue Input
1, for target value or PI input (0 V to 10 V, scalable or can be used a 4th
digital input)
Relay Output
1, programmable 30 V DC / 5 A (resistive), 250 V AC 2 A (inductive)
Serial Interfaces
RS-232
Electromagnetic Compatibility
Optional EMC filters to EN55011 Class B. (Radiated Emission: Class A)
Braking
DC Braking, Compound Braking and Electro-mechanical Brake control as
option.
Protection Level
IP66 for MICROMASTER 411
IP55 for COMBIMASTER 411
Operating Temperature
-10 °C to +40 °C (50 °C with derating)
Storage Temperature
-40 °C to +70 °C
Humidity
99% RH – non-condensing
Operational Altitudes
Up to 1000 m above sea level without derating
Protection Features
Undervoltage, Overvoltage, Short circuit, Stall Prevention, Motor
Overtemperature I
2
t (Option for PTC), Inverter Overtemperature
Standards CE
CE Marked
Conformity with EC Low Voltage Directive 73/23/EEC
and Electromagnetic Compatibility Directive 89/336/EEC
Design/Manufacture
In accordance with ISO 14001
Содержание COMBIMASTER 411
Страница 40: ...2 Installation Issue 03 01 MICROMASTER 411 COMBIMASTER 411 Operating Instructions 40 6SE6400 5CA00 0BP0 ...
Страница 60: ...3 Commissioning Issue 03 01 MICROMASTER 411 COMBIMASTER 411 Operating Instructions 60 6SE6400 5CA00 0BP0 ...
Страница 92: ...6 Troubleshooting Issue 03 01 MICROMASTER 411 COMBIMASTER 411 Operating Instructions 92 6SE6400 5CA00 0BP0 ...
Страница 98: ...7 Specifications Issue 03 01 MICROMASTER 411 COMBIMASTER 411 Operating Instructions 98 6SE6400 5CA00 0BP0 ...
Страница 102: ...8 Options Issue 03 01 MICROMASTER 411 COMBIMASTER 411 Operating Instructions 102 6SE6400 5CA00 0BP0 8 4 PROFIBUS Module ...
Страница 103: ...Issue 03 01 8 Options MICROMASTER 411 COMBIMASTER 411 Operating Instructions 6SE6400 5CA00 0BP0 103 8 5 EM Brake Module ...
Страница 154: ......
Страница 162: ...MICROMASTER 411 COMBIMASTER 411 Operating Instructions 162 6SE6400 5CA00 0BP0 ...
Страница 163: ...Issue 03 01 Geräteansicht MICROMASTER 411 COMBIMASTER 411 Operating Instructions 6SE6400 5CA00 0BP0 163 ...