OPERATION
3-21
Document No.: COM-00-05-16 June 2006, Revised June 2014
Version: C.1
Table 3-2 continued
Classification
Log Entry
Description
Warning
Flushed XPORT input on
invalid.
Means that an unknown message was received
by the Ethernet XPort component and that the
message was discarded along with any others
that might have been queued up in the serial
pipe between the XPort component and the
WAG main CPU. The entry means a loss of
either UDP or TCP traffic or possibly the loss
of a maintenance message that gets routinely
passed from the XPort to the WAG main CPU.
Typically the log means that a great deal of
Ethernet inbound traffic is occurring and an
inbound frame had to be discarded.
Warning
WAG has invalid
configuration
On power-up, the WAG conducts checks on its
own configuration. If anything is incorrect, the
WAG selects a default set of configuration and
then makes this log entry before it starts
operating.
Warning
WARNING: Echelon
device shares our
Echelon address
Means that the WAG discovered an Echelon
device on the Echelon interface, which has the
same subnet and node address as itself.
Correct the problem by reconfiguring either
the WAG Echelon address or by reconfiguring
the Echelon address of the other device.
Warning
WARNING: Received
XPORT slipped *
Means that a message received on the
Ethernet XPort interface was missing its first
byte. May not indicate a problem since the
first byte is always a zero. This entry is
intended for Siemens Rail Automation
personnel for troubleshooting.
(* only if verbosity level is greater than 1)
Warning
WARNING:
<7.RRR.LLL.GGG.SS.DD>
Echelon Address
conflict <ww.xx> to
<yy.zz>
Means the indicated ATCS address was
originally heard as subnet/node address
WW.XX, however now it is heard as
subnet/node address YY.ZZ. This indicates that
more than one device shares an ATCS address
or that a user moved/reconfigured an ATCS
device on the Echelon interface.