INSTALLATION AND CONFIGURATION
2-41
Document No.: COM-00-05-16 June 2006, Revised June 2014
Version: C.1
Figure 2-56. Change Genisys Ending Station Polling Number Screen
2.
To keep the ending station number setting, press
ENTER
. To change the ending station
number setting, enter the new value and then press
ENTER
.
Entry can be any value from 0 to
64.
The user will be returned to the Second Configuration Menu.
3.
Prior to exiting the First Configuration Menu, select “Save changes then restart” to save
changes and restart the WAG.
2.6.27
Fragile Telnet Connection
When the Fragile Sockets function is enabled, if a Telnet or Serial Telnet connection exists to a
WAG and someone else attempts to make a connection, the old connection is dropped in favor of
the new one, allowing a user to steal the connection.
When the Fragile Sockets function is disabled, if a Telnet or Serial Telnet connection exists and
someone else tries to make the connection, the attempted connection is refused and the original
owner keeps the connection.
The Fragile Sockets function defaults to ENABLED so that people may walk away from their
computers or leave for the day and others may seize control of the connection.
To enable/disable Fragile Telnet Connections:
1.
On the Second Configuration Menu, select “Fragile Telnet Connections” function to be
enabled/disabled. The Select the new Fragile Telnet Connections Option screen appears.
Figure 2-57. Select the new Fragile Telnet Connections Option Screen
2.
Select the desired Fragile Telnet Connections option and press
ENTER
.