Version
MAG 5100W (7ME6520)
MAG 5100W (7ME6580)
Pressure drop
DN 15 and 25 (½" and 1"):
● Max. 20 mbar (0.29 psi) at 1 m/s (3 ft/
s)
DN 40 to 300 (1½" to 12"):
● Max. 25 mbar (0.36 psi) at 3 m/s
(10ft/s)
DN 350 to 1200 (14" to 48"):
● Insginificant
Insignificant
Test pressure
1.5 x PN (where applicable)
1.5 x PN (where applicable)
Mechanical load (vibration)
18 to 1000 Hz random in x,y, z directions
for 2 hours according to EN 60068-2-36
Sensor: 3.17 grms
Sensor with compact MAG 5000/6000
transmittter mounted: 3.17 grms
Sensor with compact MAG 6000 I trans‐
mitter mounted: 1.14 grms
18 to 1000 Hz random in x,y, z directions
for 2 hours according to EN 60068-2-36
Sensor: 3.17 grms
Sensor with compact MAG 5000/6000
transmittter mounted: 3.17 grms
Sensor with compact MAG 6000 I trans‐
mitter mounted: 1.14 grms
Process fluid temperature
NBR
-10 to +70 °C (14 to 158 °F)
-
EPDM
-10 to +70 °C (14 to 158 °F)
-
EPDM (MI-001)
+0.1 to +30 °C (32 to 76 °F)
-
EPDM (PTB K 7.2)
+0.1 to +50 °C (32 to 122 °F)
-
Ebonite
-
-10 to +70 °C (14 to 158 °F)
EMC
EMC 2004/108/EC
EMC 2004/108/EC
1)
Maximum operating pressure decreases with increasing operating temperature
2)
MAG 5000/6000 CT -20 to +50 °C (-4 to +122 °F)
3)
For PTB K7.2 DN50 to 150: 0.03 to 16 bar DN200 to 300: 0.03 to 10 bar or 0.03 to 16 bar
Table 8-4
Design
Version
MAG 5100W (7ME6520)
MAG 5100W (7ME6580)
Housing and flange material
Carbon steel, with corrosion-resistant
two-component epoxy coating (min. 150
µm)
Corrosive category C4, according to
ISO 12944-2
Carbon steel ASTM A 105, with corro‐
sion-resistant two-component epoxy
coating (min. 150 µm)
Measuring pipe
AISI 304 (1.4301)
AISI 304 (1.4301)
Electrodes
Hastelloy
Hastelloy
Grounding electrodes (standard
Hastelloy
Hastelloy
Terminal box
Fibre glass reinforced polyamide
Fibre glass reinforced polyamide
Technical data
8.1 MAG 5100 W
SITRANS FM MAG 5100 W
Operating Instructions, 01/2020, A5E03063678-AC
51
Содержание 7ME652
Страница 6: ...Table of contents SITRANS FM MAG 5100 W 6 Operating Instructions 01 2020 A5E03063678 AC ...
Страница 10: ...Introduction 1 9 Notes on warranty SITRANS FM MAG 5100 W 10 Operating Instructions 01 2020 A5E03063678 AC ...
Страница 22: ...Description 3 3 Theory of operation SITRANS FM MAG 5100 W 22 Operating Instructions 01 2020 A5E03063678 AC ...
Страница 40: ...Connecting 5 4 Direct burial SITRANS FM MAG 5100 W 40 Operating Instructions 01 2020 A5E03063678 AC ...
Страница 46: ...Service and maintenance 6 7 Disposal SITRANS FM MAG 5100 W 46 Operating Instructions 01 2020 A5E03063678 AC ...