5. Fit and connect electrode and coil cables as shown below.
Note:
Special cable with individual wire shields (shown as dotted lines) are only required
when using empty pipe function or long cables.
1)
24 V max. 30 mA
Vx 3 to 30 V
max. 110 mA
0/4 - 20 mA
Load ≤ 800 Ω
Sensor
Positive:
Negative:
Counter or PLC-Digital input
Menu setup
Outputs
PLC-Digital input
Coil cable
Sensor connection
Electrode cable
Relay output
Digital input
11 to 30 V DC
Relay
24 V DC/1A
42 V AC/2A
NC
Shield
Common
NO
Digital output
Current output
(Powered from transmitter)
Power supply
115 to 230 V AC
Passive output
(External powered)
Active output
(Powered from transmitter)
Input
R =
Transmitter
Pull up/down resistor
1to 10 KΩ may be
required - depending on
Cables/Input resistance
Reserved for communication modules
11 to 30 V DC/11 to 24 V AC
Brown
Black
Blue
Blue
Brown
R
R
1)
L1
N
1
2
85
78
0
77
86
84
83
82
81
45
46
44
57
58
56
31
32
57
58
56
85
0
86
84
83
82
81
PE
PE
N
L
91
92
93
94
95
96
97
Connecting
5.1 Remote installation
SITRANS FM MAG 5100 W
36
Operating Instructions, 01/2020, A5E03063678-AC
Содержание 7ME652
Страница 6: ...Table of contents SITRANS FM MAG 5100 W 6 Operating Instructions 01 2020 A5E03063678 AC ...
Страница 10: ...Introduction 1 9 Notes on warranty SITRANS FM MAG 5100 W 10 Operating Instructions 01 2020 A5E03063678 AC ...
Страница 22: ...Description 3 3 Theory of operation SITRANS FM MAG 5100 W 22 Operating Instructions 01 2020 A5E03063678 AC ...
Страница 40: ...Connecting 5 4 Direct burial SITRANS FM MAG 5100 W 40 Operating Instructions 01 2020 A5E03063678 AC ...
Страница 46: ...Service and maintenance 6 7 Disposal SITRANS FM MAG 5100 W 46 Operating Instructions 01 2020 A5E03063678 AC ...