Operation
5-14
Operating instructions ULTRAMAT 23 gas analyzer
C79000-B5276-C216-03
Ser.
No.
:
X
X
-
XXX
Revision
:
X
Order
No.
:
MB23300000000000000
573
Status
Diagnostic
values
Fact.
settings
hard
Fact.
settings
soft
57
Firmware
No.
S79610
-
G210
-
A900
Softversion:
2.05.04
from
30.03.00
3.0
574
IR
diagnostic
values
O2
diagnostic
values
Pressure
sens.
diagn
Other
diagn.
values
572
Power/IR
Source
Reference/Bridge
Temperature
of
LCD
Analog
Output
5724
Pressure
ADU:
X.XXX
V
Pressure
amb.
air:
5723
Sensorsig.:XX.XX
mV
O2
:XX.XX
%
Inst.date
:XX.XX.XXXX
Inst.volt.:XX.XX
mV
5722
Logbook/Faults
Maintenance
request
AUTOCAL
deviation
O2
sensor
status
571
Level
1
required
Choose
component
Level
1
required
IR
Drift
readings
XXX
AUTOCAL
Deviation
:
XXX.XX
%
Max.allowed:
XXX.XX
%
5713
No
maintenance
request
registered
press
ENTER
to
clear
next
message
with
-
>
5712
O2
Sensor
status
Reading
:
xx.xx
mV
Maint.Req.:
6.00
mV
Fault
:
5.00
mV
5714
Flow
too
low
during
AUTOCAL
press
ENTER
to
clear
next
message
with
-
>
5711
Lockin
-
ADU
+
temp.
V
-
ADUt
Raw
values
Not
limited
concen.
5721
Choose
component
Raw
values
NNNNN
:
XXX.XX
%
NNNNN
:
XXX.XX
%
NNNNN
:
XXX.XX
%
5721c
NNNNN
V(T):
XXXXXX
NNNNN
V(T):
XXXXXX
NNNNN
V(T):
XXXXXX
T: XX.X°C TS:*****°C
5721b
XXXXX
mg/m3
NNNNN
M1
XXXXX
mg/m3
NNNNN
M2
XXXXX
mg/m3
NNNNN
M3
XX.XX
%
O
2
M
4
5721d
Lockin
-
ADU
NNNNN
X=
XXXXXX
Y=
XXXXXX
R=
XXXXXX
V=
XXXXXX
B=
XXXXXX
T=
XX.X
C
5721a
NNNNN
XX.XX
0
/20mA
NNNNN
XX.XX
0
/20mA
NNNNN
XX.XX
0
/20mA
NNNNN
XX.XX
0
/20mA
5724d
LCD temp. : XX.XX°C
5724c
Reference
:
X.XXX
V
Bridge
:
X.XXX
V
5724b
Power
(VAC):
XXX
%
Raw
voltage:XX.X
V
Source
1
:XX.XXX
V
Source
2
:XX.XXX
V
5724a
XXXX
mbar
Fig. 5-4
Menu sequence for ”Analyzer status”
Содержание 7MB2335
Страница 2: ......
Страница 8: ...I 4 Operating Instructions ULTRAMAT 23 Gas Analyzer C79000 B5276 C216 03 ...
Страница 22: ...Installation Guidelines 2 8 Operating instructions ULTRAMAT 23 gas analyzer C79000 B5276 C216 03 ...
Страница 112: ...Shut down 7 4 Operating instructions ULTRAMAT 23 gas analyzer C79000 B5276 C216 03 ...
Страница 113: ...8 1 Operating instructions ULTRAMAT 23 gas analyzer C79000 B5276 C216 03 Spare Parts List 8 ...
Страница 133: ...Spare parts list 8 21 Operating instructions ULTRAMAT 23 Gas analyzer C79000 B5276 C216 03 ...
Страница 137: ...Spare parts list 8 25 Operating instructions ULTRAMAT 23 Gas analyzer C79000 B5276 C216 03 ...
Страница 156: ...Appendix 9 4 Operating instructions ULTRAMAT 23 gas analyzer C79000 B5276 C216 03 Your comments please ...
Страница 164: ...Appendix 9 12 Operating instructions ULTRAMAT 23 gas analyzer C79000 B5276 C216 03 ...
Страница 166: ...Appendix 9 14 Operating instructions ULTRAMAT 23 gas analyzer C79000 B5276 C216 03 ...
Страница 167: ......