Antennas
6.7 SIMATIC RF660A
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
335
6
6GT2812--0
0AA0x
E
Electrical data
Range
See section "Maximum read/write ranges of
transponders (Page 59)"
Impedance
50
വ
Polarization
Circular
VSWR (standing wave ratio)
ื
2
Power
ื
2 W
IInterfaces
Plug connection
RP-TNC coupling (for connection of the an-
tenna cable)
M
Mechanical specifications
Material
PA 12
Color
Pastel turquoise
Tightening torque (at room temperature)
ื
2 Nm
P
Permitted ambient conditions
Ambient temperature
x
During operation
x
-25 ... +75 °C
x
During transportation and storage
x
-40 ... +85 °C
Degree of protection
IP67
Shock resistant to EN 60068-2-27
25.5 g
2)
Vibrations according to EN 60068-2-6
1 g
2)
D
Design, dimensions and weight
Dimensions (H x W x D)
313 x 313 x 80 mm
Weight
1.6 kg
S
Standards, specifications, approvals
Proof of suitability
CE (ETSI EN 302208), FCC (Title 47, Part
15.247), cULus
MTBF
228310 years
1)
The values differ for different dimensions/materials of the mounting surface.
2)
The values for shock and vibration are maximum values and must not be applied continuously.