Readers
5.3 SIMATIC RF615R
SIMATIC RF600
128
System Manual, 06/2019, J31069-D0171-U001-A22-7618
Voltage infeed from an external source is shown here for 12 V as an example. Other
voltages are also permissible.
5
5.3.1.5
Pin assignment of the power supply interface (X80 24VDC)
Table 5- 15
Pin assignment of the RS422 interface (reader end)
View of interface
((M12 socket, 8-p
pin)
Pin
Wire colors
Assignment
1
White
+ 24 V
2
1)
Brown
- Tx
3
Green
0 V
4
1)
Yellow
+
Tx
5
1)
Gray
+ Rx
6
1)
Pink
- Rx
7
--
Unassigned
8
--
Earth (shield)
1)
These pins are not required if the reader is operated via Ethernet.
Note
R
Requirement for external power sources
The reader must only be supplied with power by power supply units that meet the
requirements of LPS (Limited Power Source) and NEC Class 2.
R
Requirement for external power sources
The reader must only be supplied with power by power supply units that meet the
requirementsof limited power source (LPS) and NEC Class 2.
Spécification des sources de tension externes
L'alimentation du plot de lecture/écriture doit être exclusivement assurée par des blocs
d'alimentation conformes aux spécifications des sources à puissance limitée (Limited Power
Sources LPS) et de NEC class 2.