Technical specifications
SCALANCE S615
64
Operating Instructions, 10/2022, C79000-G8976-C389-07
SCALANCE S615
Ambient temperature
During operation
Vertical mounting position
•
-40 °C ... +70 °C
Horizontal mounting position:
•
Without installation frame:
-40 °C ... +60 °C
•
With mounting frame
-40 °C ... +40 °C
During storage
-
40 ℃ to +80 ℃
During transportation -
40 ℃ to +80 ℃
Relative humidity
During operation
≤ 95%
at 25 °C, no condensation
Design, dimensions and weight
Module format
Compact module S7-1500
Degree of protection
IP20
Weight
400 g
Dimensions (W x H x D)
34.8 x 151 x 134.7 mm
Installation options
•
Wall mounting
•
Mounting on a DIN rail
•
Mounting on an S7-300 standard rail
•
Mounting on an S7-1500 standard rail
•
Installation in a 19" rack
•
Mounting on a pedestal
Mounting position
•
Vertical (ventilation openings at the top and
bottom)
•
Horizontal (ventilation openings to the right
and left)
See
Permitted ambient conditions
.
Product functions
Configuration / management
•
Web Based Management (WBM) via HTTP and
HTTPS.
•
Command Line Interface (CLI) via Telnet and
SSH