9 SIMOSTEP specifications
02.05
© Siemens AG 1998 All Rights Reserved
9-2
FM-STEPDRIVE/SIMOSTEP (FB)
Specifications
SIMOSTEP
1FL3041 1FL3042 1FL3043 1FL3061 1FL3062
Max. torque
M
m
[Ncm] 200 400 600 1000
1500
Holding torque
M
H
[Ncm] 226 452 678 1130
1695
Rotor inertia
J
R
[kgcm²]
1.1 2.2 3.3 10.5 16
Number of steps
z
500 / 1000 / 5000 / 10000
Step angle
α
[ °
0.72 / 0.36 / 0.072 / 0.036
Systematic angle tolerance
per step
1)
∆α
s
[ ' ]
±6
Max. starting frequency
1)
f
Aom
[kHz] 5.3
4.3
Nominal current/supply
line
I
w
[A]
1.75 2.0 2.25 4.1 4.75
Resistance/coil
R
w
[
Ω
]
6.5 5.8 6.5 1.8 1.9
Current rise time constant
τ
[ms]
~7 ~9 ~10
~22
~22
Admissible
dynamic axial
[N] ~60 ~60 ~60 ~60 ~60
shaft load
2)
radial
[N] ~100 ~100 ~110 ~300 ~300
Weight (approx.)
G [kg]
2.05
3.1
4.2
8.0
11
Motor
voltage
U
[V]
325 325 325 325 325
1)
Measured at 1000 steps/revolution
2)
Applied at half-way from shaft exit (motor flange).
Characteristics common to all type sizes
•
Test voltage acc. to VDE 0530
•
Degree of protection IP41 at front shaft exit
•
Degree of protection IP56 on terminal box
•
Insulation class F
•
Shaft runout and axial runout acc. to DIN 42955 N
•
Ambient temperature, operating -20°C to +40°C*
•
Transport and storage temperature -40°C to +70°C
* Only if flange-mounting is correct
Содержание 1FL3041-0AC31-0BJ0
Страница 2: ......
Страница 6: ...II ...
Страница 8: ...IV ...
Страница 9: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 1 1 Overview 1 ...
Страница 11: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 2 1 Functional description 2 ...
Страница 14: ...2 Functional description 02 05 Siemens AG 1998 All Rights Reserved 2 4 FM STEPDRIVE SIMOSTEP FB ...
Страница 25: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 5 1 Mounting 5 ...
Страница 39: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 7 1 Setup 7 ...
Страница 41: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 8 1 Status indicators and troubleshooting 8 ...
Страница 44: ...8 Status indicators and troubleshooting 02 05 Siemens AG 1998 All Rights Reserved 8 4 FM STEPDRIVE SIMOSTEP FB ...
Страница 45: ... Siemens AG 1998 All Rights Reserved FM STEPDRIVE SIMOSTEP FB 9 1 SIMOSTEP specifications 9 ...
Страница 58: ......
Страница 59: ......