Original operating instructions
AEROVITAL
06.2018
15
Commissioning
Electrically operated unit.
Risk of fatal injury from electric shock or fire.
›
The AEROVITAL is connected directly to the 230 V AC mains power supply. However, the voltage is transformed to 12 V
low voltage in the unit. In case of overload, a safety device (thermal overload protection) in the transformer disconnects
the unit from 230 V AC mains power supply and automatically switches on again when the overload has been rectified.
›
A safety switch is also integrated for maintenance purposes. If the front panel is removed, the safety switch cuts off the
supply voltage.
To prevent personal injury or damage to property, always comply with the following instructions
›
There is a 230 V AC voltage prevailing on the power connection terminals of the unit, even when the front panel is
removed.
›
Do not remove the cover of the connecting clamps behind the top casing unit.
The unit can be commissioned following successful installation and electrical connection of the AEROVITAL.
• The Euro plug of the power cable must be properly connected to the 230 V AC mains power supply via a socket. If the
unit has been permanently connected to the 230 V AC mains power supply, the safety device belonging to this electrical
circuit must be switched on.
• Remove any transport and mounting aids prior to the commissioning.
Operation (general)
Cover flaps
›
Open the cover flaps (
a
), before the AEROVITAL is
switched on.
›
Close the cover flaps (
b
), before the AEROVITAL remains
switched off for a prolonged period.
a
b