![Side TMS 5001 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/side/tms-5001/tms-5001_instruction-manual_1264803009.webp)
Page 8 of 106
TMS 5001
3.
TECHNICAL DATA
3.1
BLOW MOULDING MACHINE SPECIFICATIONS
MAINS
Input voltage (+neutral):
Three phase 380 V
Admissible volt drops:
+ / - 5%
Frequency:
50 / 60 Hz
Admissible variation:
+ / - 5%
Total installed power capacity (Kw):
150 (1)
Average power consumption (Kw):
80 (2)
(Other optional voltages and frequencies).
HIGH AIR PRESSURE
High air pressure (bar):
40
Air quality: Dry, cold, oil free (food processing quality).
LOW AIR PRESSURE
Low air pressure (bar):
7
Necessary flow rate (m3/h):
50
Air quality:
Dry
COOLING WATER
Cooling water pressure (bar):
10 (máx)
Cooling water temperature (ºC):
8-10
Cooling power (Kcal/h).
16000
GENERAL DATA
Workplace temperature (ºC)
15 / 45
Premises:
Indoors
Relative humidity (%):
25 / 70
Noise level: 85 dB
HEATING OVEN
Total heating power capacity (Kw):
102(3)
Number of heating modules:
5
Number of heating areas:
5x16
Number of bulbs per module:
16
Voltage adjustment range:
0 to 220 V
Содержание TMS 5001
Страница 1: ...TMS 5001 INSTRUCTIONS MANUAL OPERATION MANUAL ...
Страница 18: ...Page 17 of 106 TMS 5001 MACHINE ...
Страница 19: ...Page 18 of 106 TMS 5001 TOOL FOR MOULD COLOCATION Block mould ...
Страница 21: ...Page 20 of 106 TMS 5001 1 A B ...
Страница 23: ...Page 22 of 106 TMS 5001 2 3 UP UP DOWN and LEVEL DOWN and CONTACT DOWN and CONTACT ...
Страница 106: ...Page 105 of 106 TMS 5001 H 10 30 ...
Страница 107: ...Page 106 of 106 TMS 5001 if A B then A B A B A B ...