![Side TMS 5001 Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/side/tms-5001/tms-5001_instruction-manual_1264803077.webp)
Page 76 of 106
TMS 5001
1. First, adjust the protections of the preform neck to the
new format. Loosen the screws shown in the picture
both at oven entrance and exit.
2. Place a preform inside the nozzle on each end of the oven.
3. By regulating the slotted brackets, we can set the
optimal distance.
4. Then check whether measure “Y” equals 25mm
approximately. This measure is also an approximate one and
before modifying the position of the bulbs you are advised to
define the thermal profile, modifying their voltage parameters.
Still, if you are working with very little or very big preforms, you
might have to bring the bulbs closer to the preforms or separate
them instead.
5. In order to modify the position of the bulbs it is necessary to remove the oven
modules from the machine. First, turn the electric switch off.
Y:~25 mm