Page 44 of 106
TMS 5001
-
Movement “Y”: indicates the state of the SV of the “Y” Movement Table pneumatic cylinder in the
preform loader’s positioning system and the detectors that identify the end of the process.
-
Rotative T. Right: indicates the state of the SV of the Rotating Right Turn pneumatic cylinder in the
preform loader’s positioning system and the detectors that identify the end of the process.
-
Rotating T. Left: indicates the state of the SV of the Rotating Left Turn pneumatic cylinder in the
preform loader’s positioning system and the detectors that identify the end of the process.
-
Movement “X”: indicates the state of the SV of the “X” Movement Table pneumatic cylinder in the
preform loader’s positioning system and the detectors that identify the end of the process.
-
Load elevator: indicates the state of the SV of the loading system’s pneumatic elevation cylinder and
the detectors that identify the end of the process.
-
Fix Preform: indicates the state of the SV of the loading system’s pneumatic preform fixing cylinder
and the detectors that identify the end of the process.
Parameters of the loader (1/2)
-
Hopper Belt Speed: The speed is introduced as a percentage of the maximum speed allowed by the
variable-speed drive to the minimum.
-
Ascent Speed Belt Vibrator:
time taken
(in seconds) for the pneumatic vibrator, installed in the base
of the preform loading belt in chute 2, to move.
-
Elev. speed Belt:
speed of the preform loading belt. The speed is introduced as a percentage of the
maximum speed allowed by the variable-speed drive to the minimum.
-
Preform Position. Rollers Speed: speed of the roll that loads all the preforms on the elevator.
-
Cyc. without Min. Lvl.: number of cycles without a minimum level of preform before a loading alarm is
triggered.
Options of the Loader (1/2)
-
Cycle Counter: it counts the number of loading cycles. This option and the associated parameter are
used to programme a certain amount of production. Once the programmed number of cycles has
been completed, the loading system is automatically deactivated. It also indicates the current
number of cycles to stop the preform loader.
-
Pref. Counter: it activates and deactivates the preform photoelectric cell counter at the exit of the
loading area. If it is deactivated, there will be no real control over the preforms that are being loaded
or of their presence.
Содержание TMS 5001
Страница 1: ...TMS 5001 INSTRUCTIONS MANUAL OPERATION MANUAL ...
Страница 18: ...Page 17 of 106 TMS 5001 MACHINE ...
Страница 19: ...Page 18 of 106 TMS 5001 TOOL FOR MOULD COLOCATION Block mould ...
Страница 21: ...Page 20 of 106 TMS 5001 1 A B ...
Страница 23: ...Page 22 of 106 TMS 5001 2 3 UP UP DOWN and LEVEL DOWN and CONTACT DOWN and CONTACT ...
Страница 106: ...Page 105 of 106 TMS 5001 H 10 30 ...
Страница 107: ...Page 106 of 106 TMS 5001 if A B then A B A B A B ...