![Side-Power EB 20/110 S Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/side-power/eb-20-110-s/eb-20-110-s_installation-and-user-manual_1264827015.webp)
15
EB 20/110 S - EB 40/160 S - EB 60/160 S - EB 75/185 S - EB 90/185 S
1.0.6 - 2014
Elektrisk installasjon
N
Electrical installation
GB
Maximum cable length
1
Minimum cable dimension
Maksimum kabel lengde 1
Minumum kabel dim.
Reguired min. battery capacity
Anbefalt min. batteri kapasitet
XF
Thruster
Motor V/
kW
Thrust (KG)
Skyvekraft
Length
Lengde
Dim.
2
mm
2
- AWG
Ah/V
CCA ( SAE)
Rec. fuse amp.
Anbefalt sikr. amp.
EB 20
12/1.6
20
1-5
50-1/0
60 Ah/12V
550
150
EB 40
12/2
40
1-4
4-8
50-1/0
70-2/0
115 Ah/12V
800
250
EB 60
12/5.0
60
1-10
10-20
95-3/0
120-4/0
115Ah/12V
800
325
EB 60
24/5.0
60
1-10
10-20
95-3/0
95-3/0
115Ah/24V
800
250
EB 75
12/6.0
75
1-10
10-20
95-3/0
120-4/0
115Ah/12V
800
325
EB 75
24/6.0
75
1-10
10-20
95-3/0
95-3/0
150Ah/24V
1050
325
EB 90
12/6.5
90
1-10
10-20
95-3/0
120-4/0
115Ah/12V
800
325
EB 90
24/6.5
90
1-10
10-20
95-3/0
95-3/0
150Ah/24V
1050
325
1) The distance from the thruster unit to the battery, one way, each able. Use of even larger cable dimensions and battery capacity will give the thruster better performance.
2) Wiring insulation rating is 105
o
C ( 221
o
F) minimum.
1) Avstanden mellom thruster enheten og batteri, en vei for hver kabel ( sum av plusskabel og minuskabel). Ved å benytte kabler med enda større tverrsnitt vil det oppnås økt
skyvekraft.
2) Skyvekraft er oppgitt ved 10,5V (21V) driftspenning.
3) Krav til kabelisolasjon er minimum 105
0
C (221
o
F).
Viktig angående EB 20!
Denne skal kjøres med like lang pausetid som driftstid.
Max kont. kjøreperiode er 30 sek. Eksempel: kjør 10 sek,
vent 10 sek eller kjør 20 sek, vent 20 sek, osv.
Important regarding EB 20!
This should be run with the same amount of break time as running
time. Max cont. running time is 30 seconds. Example: run 10 sec-
onds, wait 10 seconds or run for 20 seconds, wait 20 seconds, etc.