4
MOUNTING
78
8026365/V1-0/2022-03|SICK
S U P P L E M E N T A R Y O P E R A T I N G I N S T R U C T I O N S | VMS4200-x/5200-x MID
Subject to change without notice
4.1.3
Mounting the telescopic tube on the frame
Fig. 75: Mounting the telescopic tube on the frame
▸
Attach the telescopic tube to a profile using the mounting and spring plate that is pre-
mounted on the base tube.
4.1.4
Fastening the LiDAR sensors to the mounting plates
Fig. 76: Fastening the LiDAR sensors to the mounting plates
Each mounting plate has an injection bush on its rear side to accommodate the LiDAR
sensor. This coding prevents the device from being incorrectly rotated by 180° when
mounted.
▸
Insert the injection bush of the mounting plate into the locating hole of the LiDAR
sensor.
▸
Press the device into place with one hand and screw the device to the mounting plate.
▸
Make sure that the device is securely screwed on.
Mounting
Mounting