3
SYSTEM DESCRIPTION
30
8026365/V1-0/2022-03|SICK
S U P P L E M E N T A R Y O P E R A T I N G I N S T R U C T I O N S | VMS4200-x/5200-x MID
Subject to change without notice
Fig. 19: Triggering of recording of measured values for systems with object detection
Legend
A
Cross-belt signal
B
Object trigger signal
C
Reading interval
1
Reading interval is opened by the object trigger and closed by the
cross-belt signal.
2
Reading interval is opened by the cross-belt signal and closed by the
object signal.
3
Reading interval is opened and closed by the object trigger.
4
Reading interval is opened and closed by the cross-belt signal.
•
Just like for the system variant without object detection, the reading interval
determines the start and end of the measuring process.
•
Depending on the position of the object on the cross-belt conveyor element, it is jointly
determined from the object trigger and cross-belt signal.
Triggering of recording
of measured values
with object detection