SYSTEM DESCRIPTION
3
71
8026365/V1-0/2022-03|SICK
Subject to change without notice
S U P P L E M E N T A R Y O P E R A T I N G I N S T R U C T I O N S | VMS4200-x/5200-x MID
3.10.3
Mounting requirements
▸
Use a stable frame that is secured to prevent twisting and has sufficient load-bearing
capacity.
▸
Attach the frame to the conveying system in such a way that it cannot shake or vibrate.
▸
Align the frame at a right angle to the conveying direction.
NOTE!
Use Item aluminum profiles.
Fig. 68: Working range of the LMS4x21
Legend
1
Maximum working sensing range: 3 m
2
Zero point of the distance measurement. In the delivery state, this point
is the origin of the laser (marked with a point on the upper and lower
side of the housing).
3
Minimum distance between the zero point of the measurement and the
measuring object: 900 mm
4
Aperture angle: 70°
Frame
LMS4x21