Operating Instructions
Chapter
11
UE4740
8020182/1CUO/2022-08-26
©
SICK AG • Industrial Safety Systems • Germany • All rights reserved
39
Subject to change without notice
Annex
11.2.2
Output signals from the FPLC to the EFI connection
EFI1 address
2.7
2.6
2.5
2.4
2.3
2.2
2.1
2.0
EFI2 address
4.7
4.6
4.5
4.4
4.3
4.2
4.1
4.0
C4000 Standard/Advanced
Reserved
Activate
teach-in
Operating mode switching
6
5
4
3
2
1
M4000 Advanced
Reserved
Muting
lamp
status
Reset/
override or
reset
Override or
additional
signal C1
or belt stop
Muting sensors
B2
B1
A2
A1
M4000 Advanced with UE403
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
S3000
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
S300
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
EFI1 address
3.7
3.6
3.5
3.4
3.3
3.2
3.1
3.0
EFI2 address
5.7
5.6
5.5
5.4
5.3
5.2
5.1
5.0
C4000 Standard/Advanced
Bypass
channel 2
Bypass
channel 1
Reserved
Reserved
Reserved
Run-on
monitoring
(SCC)
Bottom
dead
centre
(MCC-BDC)
Top dead
centre
(MCC-TDC)
M4000 Advanced
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
M4000 Advanced with UE403
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
S3000
In D2
In D1
In C2
In C1
In B2
In B1
In A2
In A1
S300
Reserved
Reserved
Reserved
Reserved
In B2
In B1
In A2
In A1
Tab. 18: Process image of the output signals from the FPLC to the EFI connection
11.3
Diagnostics data UE4740
The diagnostics data for the UE4740 can be read via an acyclic read on API 0, slot 1,
subslot 1 with the index 0xe00c (diagnostics, maintenance, qualified and status for one
AR). The diagnostics data set is part of the reply to the acyclic read and is only present if
diagnostics are available. If there are no diagnostics in the device, the reply comprises only
the related ReadResponseHeader.
The diagnostics data set has the following structure, where the actual diagnostics data for
the UE4740 start at byte 20:
Range
Meaning
Byte 0
–
5
Block header
Byte 6
–
9
API
Byte 10
–
11
SlotNumber
Byte 12
–
13
SubslotNumber
Byte 14
–
15
ChannelNumber
Byte 16
–
17
ChannelProperties
Byte 18
–
19
Userstructureidentifier
Byte 20
–
21
ChannelNumber
Byte 22
–
23
ChannelProperties
Byte 24
–
25
ChannelErrorType
If there are more diagnostics data in the device, the additional diagnostics consisting of
ChannelNumber, ChannelProperties and ChannelErrorType are appended:
Tab. 19: Diagnostics data of
the UE4740