Product description
Display
Meaning
U
S
Reserved
No supply voltage
Red
Internal supply voltage too low or
firmware is being updated
U
L
Green
Voltage supply OK
PROFIBUS is working but safety communication is inactive. No
PROFIsafe master was detected.
Green
PROFIBUS is working with PROFIsafe, safety communication is
active
Green
Acknowledgement by user mandatory
Red
General PROFIBUS error, no communication is possible
BUS
Red
Not a valid PROFIBUS configuration
Device ready for operation
Red
Configuration is being transferred or was not concluded
DIA
Red
1 Hz: System error (lock
D
out)
½ Hz (75 % on, 25 % off): Field-signal connection error)
Field-signal connection A or B is inactive
Yellow
Field-signal connection A or B is active
A
and
B
Red
Overload at field-signal connection output A or B
Device communication at connection SDL1 ( ) or SDL2 ( ) is OK.
The switching outputs (OSSDs) of the connected devices are off.
Yellow
Both switching outputs (OSSD1 and OSSD2) of the connected
device are active.
and
Red
Device-communication error at SDL connection
3.5
Configurable functions
This section describes the functions of the UE4155 bus node which are selectable via soft-
ware. Chapter 6 “Examples of circuits” on page 33 describes several typical applications
that you can realise with the aid of the functions described below.
Test the protective device after any changes!
Changes to the configuration of the devices can degrade the protective function. After eve-
ry change to the configuration you must therefore check the effectiveness of the protective
device. To this end, please observe the notes in chapter 7.3.4 “General acceptance of the
bus node” on page 38.
The person who makes the change is also responsible for the correct protective function of
the device. When making configuration changes, please always use the password hierar-
chy provided by SICK to ensure that only authorised persons make changes to the configu-
ration. The SICK service team is available to provide assistance if required.
When starting to configure the device, you may save an application name with a maximum
of 22 characters. Use this function as a “memory jog”, e.g. to describe the application of
the current device configuration. Device symbol
UE4100 PROFIsafe
, context menu
Configuration draft
,
Edit
, file card
General
.
Tab. 3: Status indicators of
the UE4155 bus node
WARNING