5
ELECTRICAL INSTALLATION
50
8027439/V1-0/2022-02|SICK
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | Track and trace cabinet TTC100-2
Subject to change without notice
PIN Signal
Function
1
IN5 +
Insulated digital switching input
2
IN5 +
Insulated digital switching input
3
IN6 +
Insulated digital switching input
4
IN6 +
Insulated digital switching input
5
IN7 +
Insulated digital switching input
6
IN8 +
Insulated digital switching input
7
24 V
Non-insulated supply voltage for external sensors
8
GND ISO (X5)
Insulated reference potential for switching inputs (X5)
*
9
24 V
Non-insulated supply voltage for external sensors
10
GND ISO (X5)
Insulated reference potential for switching inputs (X5)
*
11
24 V
Non-insulated supply voltage for external sensors
12
GND ISO (X5)
Insulated reference potential for switching inputs (X5)
*
* S2 switch in GND position: Reference potential also for 24 V (X5)
•
IN5 and IN6 are designed with redundancy
•
Max. 0.7 A total output for all 24 V supply voltage connections
•
Min. high input logic level: 12 V
•
Max. low input logic level: 4 V
•
Input frequency 30 kHz
S2 switch
•
GND ISO (X5): volt-free connection
•
GND: GND of the connected device connected to GND of the controller
Tab. 16: Connections on the
terminal block “X5 –
INPUT B”
X5 - INPUT B