3
PRODUCT DESCRIPTION
14
8027439/V1-0/2022-02|SICK
A D D E N D U M T O O P E R A T I N G I N S T R U C T I O N S | Track and trace cabinet TTC100-2
Subject to change without notice
NOTE!
The following figure shows the fully-equipped cabinet. Depending on the
application, individual components may be missing or additional components, such as
optocouplers, may be included.
Fig. 2:
Internal view of the TTC100-2 cabinet (example)
Legend
1
SIM2000-2 Prime controller with connections and SD memory card for
parameter cloning and optionally with alibi memory for legal-for-trade
systems
2
Terminals for mains voltage IN (AC 100 ... 264 V / 50 ... 60 Hz)
3
Circuit breaker for power supply modules
4
RCD (residual current device) for protective contact plug
5
Protective contact socket (mains voltage)
6
Power supply module(s) for supplying voltage to the controller as well as
the connected sensors and ICR camera systems
7
Thermostat for the fan controller
8
Circuit breaker for the connected ICR cameras
(2 circuit breakers per ICR camera)
9
24 V terminals with fuse modules for supplying voltage to the controller,
sensors and internal fans
10
Optional LFT Ethernet switch for connecting legal-for-trade system
components
11
Optional Ethernet switches for setting up an internal sensor network as
well as for outputting data and camera images
12
24 V terminals for supplying voltage to the ICR cameras
Internal view
of the cabinet