![SICK TR110 Lock Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/sick/tr110-lock/tr110-lock_operating-instructions-manual_1264391047.webp)
Table 19: Outputs
Output data
Type of output
Safety outputs
2 semiconductor outputs (OSSDs), p-switching,
short-circuit protected
Application diagnostic outputs
p-switching, short-circuit protected
Output current (OSSDs)
ON state
OFF state
1 mA … 150 mA
≤
250 µA
Output voltage (OSSDs)
ON state
OFF state
U
v
-1.5 V DC … U
v
0 V DC … 1 V DC
Test pulse duration (OSSDs)
All except for TR110-SRUCAxx
TR110-SRUCAxx
300 µs
1 ms
Test pulse interval (OSSDs)
All except for TR110-SRUCAxx
TR110-SRUCAxx
≤
100 ms
≤
140 ms
Application diagnostic outputs
Output current
Output voltage
1 mA … 50 mA
0.8 × U
v
… U
v
N/O contacts of the pushbuttons (only TR110-SXXXBXX)
Output current
Output voltage
1 … 50 mA
U
v
Table 20: Mechanical data
Mechanical data
Dimensions (W x H x D)
"Safety switch dimensional drawings",
Material
Safety switch housing
Actuating head
Plug connector
Fiberglass-reinforced thermoplastic
Zinc die cast
Nickel-plated brass
Weight
0.42 kg
Mechanical service life
1 × 10
6
switching operations
Table 21: Ambient data
Ambient data
Enclosure rating
IP 67 (IEC 60529)
IP 69 (IEC 60529)
IP 69K (IEC 20653)
Enclosure rating of the variants with operating
buttons
IP 65 (IEC 60529)
Ambient operating temperature
–20 °C … +55 °C
Vibration resistance
EN IEC 60947-5-3
EMC
EN IEC 60947-5-3
TECHNICAL DATA
11
8023119/15LY/2019-10-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | TR110 Lock
47