Electrical data
Safety switches
Locking solenoid
Pushbutton (LED)
40 mA
400 mA
10 mA
Power consumption of locking solenoid
6 W
External device protection
2)
Safety switches
Locking solenoid
0.25 A … 2 A
0.5 A … 8 A
Switch-on time of locking solenoid
100%
Contamination rating
3 (EN 60947-1)
Power-up delay
All except for TR110-SRUCAxx
TR110-SRUCAxx
1 s
< 8 s
Response time
≤
260 ms (+5 ms for each additional safety
locking device in a safe series connection)
Release time
400 ms
Discrepancy time
≤
10 ms (EN IEC 60947-5-3)
Risk time
3)
260 ms
Dwell time between successive locking/unlock‐
ing procedures
2.5 s
Rated insulation voltage Ui
50 V DC (IEC 60947-1)
Rated impulse withstand voltage U
imp
500 V (IEC 60947-5-1)
Rated short-circuit current
100 A
Locking principle
TR110-SRxxxx
TR110-SLxxxx
Closed-circuit current principle
Open-circuit current principle
1)
The locking solenoid of the TR110 Lock safety locking device is externally controlled and supplied with
power.
2)
Medium time-lag triggering characteristics.
3)
The risk time is the time needed to detect internal and external faults. External errors affect the OSSDs
(short-circuit to an OSSD and cross-circuit between the two OSSDs). At least one of the two OSSDs is
safely switched off during the risk time.
Table 18: Interfaces
Interfaces
System connection
TR110-SxxSAxx
TR110-SxxFLxx
Male connector, M12, 8-pin, A-coded
TR110-SxxCAxx
TR110-Sxx2Bxx
Male connector, M12, 8-pin, A coded, and
male connector, M12, 5-pin, A coded
11
TECHNICAL DATA
46
O P E R A T I N G I N S T R U C T I O N S | TR110 Lock
8023119/15LY/2019-10-28 | SICK
Subject to change without notice