Working range diagram
Scanning range in m (feet)
1
Scanning range in m (feet)
1
Scanning range max. 25 m (82.02 feet)
2
Scanning range typical (for objects with 10 % remission):
8 m (26.25 feet)
3
180°
‒45°
225°
270°
90°
0°
0
20
(65.62)
–20
(–65.62)
10
(32.81)
–10
(–32.81)
30
(98.43)
–30
(–98.43)
0
20
(65.62)
–20
(–65.62)
10
(32.81)
–10
(–32.81)
30
(98.43)
–30
(–98.43)
Figure 23: Working range diagram
1
Sensing range in meters (feet)
2
Maximum sensing range: 25 m
(82.02 feet)
3
Typical sensing range for objects with
10% remission: 8 m (26.25 feet)
10.2
Performance
Variant
TiM881P
Response time
Typ. 1 scan: 67 ms
Max. 2 scans: 134 ms
1)
Detectable object shape
Almost any
Measurement error
Statistical (1 σ): < 20 mm
2)
Systematic: ± 60 mm
2)
Temperature drift: 0.5 mm/K
1)
Corresponds to max. 134 ms b45° and +225° of the working range, max. 150 ms between
-45° and +45° of the working range (
see "Working range diagram", page 37
).
2)
Typical value at room temperature and up to a sensing range of 10 m at 90% remission, real value
depends on ambient conditions, temperature drift: 0.5 mm/K
10.3
Interfaces
Variant
TiM881P
Ethernet
TCP/IP
Max. data transmission rate: 10 Mbit and 100 Mbit
Length of cable: max. 100 m
USB
Type: Micro-USB
Digital inputs
4 (PNP)
Digital outputs
4 (PNP)
Optical indicators
2 LEDs
TECHNICAL DATA
10
8024355/1DRC/2021-12-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | TiM8xxP
37