10.5
Ambient data
Variant
TiM31x
TiM32x
TiM35x
TiM36x
Object remission
4% ... 1,000% (reflectors)
Electromagnetic
compatibility
(EMC)
Radiation emitted:
Residential area (EN 61000-6-3:2007-01+AMD:A1:2011)
Electromagnetic compatibility:
Industrial environment (EN 61000-6-2:2005)
Vibration resist‐
ance
Sine resonance scan:
10 Hz ...1,000 Hz
(IEC 60068-2-6:2007)
Sine test:
10 Hz ... 500 Hz; 5 g; 10 frequency cycles
(IEC 60068-2-6:2007)
Noise test:
10 … 250 Hz; 4.24 grms, 5 h
(IEC 60068-2-64:2008)
Shock resistance
50 g; 11 ms; 6 shocks/axis
25 g; 6 ms; 2.000 shocks/axis
50 g; 3 ms ; 10,000 shocks/axis
(IEC 60068-2-27:2008)
Ambient temper‐
ature
Operation: -10 °C ... +50 °C
Storage: -30 °C ... +70 °C
(IEC 60068-2-14:2009)
Commissioning/switching on:
–10 °C ... +50 °C
Operation: –25 °C ... +50 °C
Storage: –40 °C ... +75 °C
(IEC 60068-2-14:2009)
Ambient humid‐
ity
Operation: ≤ 80%, non-condensing
Storage:
≤
95%, non-condensing
(EN 60068-2-30:2005)
Altitude
< 5,000 m above sea level
Ambient light
immunity
80,000 lx
Ambient condi‐
tions
Contamination level 3 outside the housing
(EN 61010-1:2011-07)
Damp heat
+25 °C ... +55 °C, 95% r.h., 6 cycles
(EN 60068-2-30:2005)
Temperature
change
-10 °C … +50 °C, 10 cycles
(EN 60068-2-14: 2009)
-25 °C … +50 °C, 10 cycles
(EN 60068-2-14: 2009)
10
TECHNICAL DATA
54
O P E R A T I N G I N S T R U C T I O N S | TiM3xx
8024851//2021-07-21 | SICK
Subject to change without notice