LED (red)
LED (green)
Phase
-
O
Monitoring mode:
Automated return after teach-in com‐
plete
All fields free
O
O
Monitoring mode:
If a field violation has occurred
O
= illuminated;
Ö
= flashing
The taught-in field contour is automatically and permanently saved as new field set 1.
7.2.1.2
Field set selection via input wiring
One of the predefined field sets can be activated by wiring the digital inputs.
Field set factory settings – digital inputs
Field
set
Digital inputs
Field shape
Default size of field 1
IN 1
IN 2
IN 3
IN 4
1
0
0
0
0
Rectangle, segmented L: 1 m, W: 2 m
2
1
0
0
0
Rectangle, segmented L: 1.25 m, W: 2 m
3
0
1
0
0
Rectangle, segmented L: 1.5 m, W: 2 m
4
1
1
0
0
Rectangle, segmented L: 1.75 m, W: 2 m
5
0
0
1
0
Rectangle, segmented L: 1 m, W: 2 m
6
1
0
1
0
Rectangle, segmented L: 1.25 m, W: 2 m
7
0
1
1
0
Rectangle, segmented L: 1.5 m, W: 2 m
8
1
1
1
0
Rectangle, segmented L: 1.75 m, W: 2 m
9
0
0
0
1
Rectangle, segmented L: 1 m, W: 2 m
10
1
0
0
1
Rectangle, segmented L: 1.25 m, W: 2 m
11
0
1
0
1
Rectangle, segmented L: 1.5 m, W: 2 m
12
1
1
0
1
Rectangle, segmented L: 1.75 m, W: 2 m
13
0
0
1
1
Rectangle, segmented L: 1 m, W: 2 m
14
1
0
1
1
Rectangle, segmented L: 1.25 m, W: 2 m
15
0
1
1
1
Rectangle, segmented L: 1.5 m, W: 2 m
16
1
1
1
1
Rectangle, segmented L: 1.75 m, W: 2 m
Output form (rectangle), can be changed as desired, L = length, W = width
Input level: Low (in resting position): ≤ 2 V, high (in working position): ≥ 8 V
7
OPERATION
44
O P E R A T I N G I N S T R U C T I O N S | TiM3xx
8024851//2021-07-21 | SICK
Subject to change without notice