Prerequisites:
•
IO-Link master, z. B. SICK SIG200, connected to the PLC via fieldbus
•
Common PLC configuration tool, if applicable function block for the RFH5xx
installed
•
Type-specific IODDD of the RFH5xx for application in the PLC
Procedure
1.
Connect the RFH5xx to the voltage-free IO-Link master via IO-Link.
2.
Connect master to PLC via fieldbus.
3.
Load device IODD in the IO-Link master.
4.
Optional: select Data Storage in the master port configuration
5.
Configure the RFH5xx as desired.
You will find helpful information on this process in the type-specific IO-Link techni‐
cal information with a table overview of all parameters and the selectable device
parameter values,
see "Scope of delivery", page 19
6.
Commissioning through communication via the RFH5xx function block.
7.
Present the RFH5xx with a written HF transponder and generate continuous read‐
ing using the PLC. Make sure the transponder is optimally aligned to the device
when doing so,
see "Mounting the device", page 27
8.
Check the selected parameter values for suitability in operative use and optimize if
necessary.
COMMISSIONING